Wilbur-curtis WB5GT User Manual

Browse online or download User Manual for Water boiler Wilbur-curtis WB5GT. Wilbur Curtis WB5GT User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Important Safeguards/Symbols
Models Included
• WB5GT
Service Manual – WB5GT Water Boiler
Wilbur Curtis Company, inC.
Symbols:
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
This equipment is designed for commercial use. Any servicing other than cleaning and routine maintenance
should be performed by an authorized Wilbur Curtis Company service technician.
DO NOT immerse the unit in water or any other liquid
To reduce the risk of re or electric shock, DO NOT opens service panels. There are no user service-
able parts inside.
Keep hands and other items away from hot areas of the unit during operation.
Never clean with scouring powders or harsh chemicals.
CAUTION: DO NOT
connect the unit to
hot water supply.
The inlet valve is not rated for
hot water.
CAUTION: Follow
this setup procedure
before attempting
to use this unit. Failure to
follow these instructions can
result in injury and/or void of
warranty.
ISO 9001:2008 REGISTERED
WILBUR CURTIS CO.
6913 Acco Street,
Montebello, CA 90640-5403
For the latest information go to
www.wilburcurtis.com
Tel: 800/421-6150
Fax: 323/837-2410
CAUTION:
Equipment must be
installed to comply
with applicable federal, state,
and local plumbing/electrical
codes.
INSTALLATION
This Curtis unit is pre-set and ready to go from the factory.
System Requirements:
• Water Supply 20 – 90 PSI (MINIMUM FLOW RATE of 2 GPM)
• Electrical: See electrical schematic.
3. Connect the unit to electrical outlet with appropriate amperage rating (See serial tag on machine).
4. Once power has been supplied to the unit, ip the toggle switch to the ‘ON’ position (located on the rear of
the unit), the water tank will begin to ll. When the water level in the tank reaches the probe, the heating
element will turn on.
5. Water in the heating tank will require 60 to 70 minutes before reaching operating temperature (factory
setting of 204°F).
NSF requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so
that the unit can be moved for cleaning.
2. Thisunitmustbeinstalledwithadequatebackowprotectiontocomplywithapplicablefederal,
state and local codes.
3.Waterpipeconnectionsandxturesdirectlyconnectedtoaportablewatersupplyshallbesized,
installed and maintained in accordance with federal, state, and local codes.
NOTE:Awaterltrationsystemmustbeusedtohelpmaintaintrouble-freeoperation.Air must be
purged from the cartridge prior to connection to equipment. Inareaswithextremelyhardwater,we
highlyrecommendtheuseofaCurtisapprovedwaterlter.Forourfulllineoflters,pleaselogonto
www.wilburcurtis.com.
SETUP STEPS
1. The unit should be level (left to right - front to back), on a secure surface.
2. Connect the water line to the water inlet tting on the rear of the unit. Water volume going to the machine
should be consistent. Use tubing sized sufciently to provide a minimum ow rate of two gallons per
minute.
1
Forthelatestspecicationsandinformationgotowww.wilburcurtis.com
Technical support: 1-800-995-0417 M-F 5:30am-4:00pm pst
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Wilbur Curtis Company, inC

Important Safeguards/SymbolsModels Included• WB5GTService Manual – WB5GT Water BoilerWilbur Curtis Company, inC.Symbols:WARNINGS – To help avoid perso

Page 2 - I/O FUNCTION

READYON/OFFTEMP AERATIONOTHER FEATURESLED SCREEN DISPLAYWhen the unit is on and not in programming mode, the UCM will stay on and the LED screen will

Page 3 - PARTS LIST

ILLUSTRATED PARTS LIST3Continued on page 4123457891011121314151618192021222324252627283032291731336PARTS LISTITEM Nº PART NºDESCRIPTION 1 2 3 4 5

Page 4

4PARTS LISTITEM Nº PART NºDESCRIPTION 7 7A 8 9101112131415161717A1818A192021222324252627282930313233WC-62045WC-62044WC-5502-01*WC-37266WC- 934-04*

Page 5

ELECTRICAL SCHEMATIC 120/220V SINGLE PHASE5

Page 6

6ELECTRICAL SCHEMATIC 220V THREE PHASE

Page 7 - WB5GT ROUGH-IN DRAWING

7Curtis can provide and optional wall mount assembly that allows you to place your Curtis water boiler against a wall surface. The water boiler may be

Page 8 - Product Warranty Information

ECN 15688 . 3/19/[email protected] . rev LECN 15719 . 3/11/14 @ 9.6 . Rev KECN 15220 . 7/31/13 @ 15.8_Rev jECN 13852 . 2/21/[email protected] 13355 . 7/20/[email protected] 1

Comments to this Manuals